The pin count follows the signal, not the cable length
Every M12 A-coded cable in this range shares the same thread and IP67 connector body, so the first real decision is how many conductors your device actually needs. A 2-pin cable carries one signal or power pair. A 5-pin cable covers most standard sensor and actuator connections. An 8-pin cable gives you extra conductors for more complex signal or data runs.
Once you know the pin count, the second decision is whether the cable must be shielded. Only the 8-pin assembly here is shielded; the 2-pin and 5-pin versions are unshielded. That difference matters when the cable runs near drives, inverters, or other noise sources.
What the 2-pin and 5-pin cables give you
- M12 A-Coded 2-Pin Female to Female Sensor Cable PUR IP67 Drag Chain Rated: M12 A-coded 2-pin female-to-female cable with AWG22 conductors, unshielded, PUR jacket, IP67, drag-chain capable, rated max 60 V DC and 4 A per contact. This is the simplest option for a single low-voltage sensor or actuator pair. The 2-pin layout leaves no spare conductors, so confirm your device only needs one signal or power pair before ordering.

M12 A-Coded 2-Pin Female to Female Sensor Cable PUR IP67 Drag Chain Rated - M12 A-Coded 5-Pin Female to Female Sensor Cable PUR IP67 Drag Chain Rated: M12 A-coded 5-pin female-to-female cable with AWG22 conductors, unshielded, PUR jacket, IP67, drag-chain capable, rated max 60 V DC and 4 A per contact, approved to UL AWM 20549. Five pins is the common middle ground for standard sensors, actuators, and control signals. It gives you more conductors than the 2-pin version without the extra cost or bulk of an 8-pin shielded assembly.

M12 A-Coded 5-Pin Female to Female Sensor Cable PUR IP67 Drag Chain Rated
When the 8-pin shielded cable is the better fit
The 8-pin version is the only cable here with 360° EMI shielding. If your signal run shares a cabinet or cable tray with variable-frequency drives or other high-energy switching equipment, that shield can help protect the signal. The trade-off is a slightly larger, less flexible assembly and a higher catalog price than the unshielded 2-pin and 5-pin cables.
The 8-pin cable is also the one with a stated fieldbus compatibility note: the catalog lists it as compatible with common industrial fieldbus protocols such as Profibus, DeviceNet, and CC-Link. If you are wiring a fieldbus drop rather than a simple discrete sensor, start there rather than trying to force a 5-pin cable into an 8-pin device port.
Shielded 8-pin evidence
- M12 A-Coded Female to Female 8-Pin Sensor Cable, Shielded PUR Drag Chain, IP67: M12 A-coded 8-pin female-to-female cable, fully shielded for 360° EMI protection, halogen-free PUR jacket, IP67, drag-chain capable, AWG24 conductors, max 4 A per contact, UL AWM 20549. Choose this when your device port has 8 positions or when the signal run needs shielding. The AWG24 conductors are smaller than the AWG22 used on the 2-pin and 5-pin cables, so check that your current draw stays within the 4 A per contact rating.
Shared limits across all three cables
These three assemblies share the same connector style, protection rating, and temperature window. The differences come down to pin count, shielding, and conductor size.
- Connector and gender: All three are M12 A-coded female-to-female with straight connectors on both ends. They join two female ports or extend an existing female-ended lead; they do not convert to a male thread.
- Ingress protection: All three are rated IP67 at the connectors, which covers dust and temporary water immersion. That rating applies to the mated connector pair, not to an unmated plug left exposed.
- Voltage and current: All three list a maximum operating voltage of 60 V DC and a maximum current of 4 A per contact. The 8-pin cable uses AWG24 conductors, while the 2-pin and 5-pin cables use AWG22.
- Temperature range: Moving: −30 °C to +70 °C. Fixed: −40 °C to +80 °C. The narrower moving range is the one that applies inside a drag chain.
- Lengths and ordering: All three are available in lengths from 0.3 m to 20 m and are supplied subject to minimum order quantities. The catalog does not list a default length, so specify the length you need when requesting a quote.
A short checklist before you order
- Count the positions in the device port: A 5-pin cable will not seat correctly in an 8-position port, and an 8-pin cable will not fit a 5-position port. Match the pin count to the port, not to the number of wires you plan to use.
- Decide whether shielding is required: If the run is near drives or other noise sources, the shielded 8-pin cable is the only shielded option in this set. If the run is short and clean, the unshielded 2-pin or 5-pin cable is simpler and less expensive.
- Check the current per contact: All three cables are rated at 4 A per contact. If your device draws more than that on any single conductor, none of these assemblies is the right choice.
- Confirm the cable will move: All three are drag-chain capable, but the moving temperature range is narrower than the fixed range. Route and support the cable according to the drag-chain application, not as a fixed install.